Skip to Main Content

Incident to the Airbus A320 registered HA-LWT and operated by Wizz Air on 29/08/2017 near Cluj-Napoca [Investigation led by TSB / Hungary]

Pompage du moteur N°1 en montée initiale, arrêt commandé du moteur puis déroutement

Responsible entity

Hungary - TSB

 

Preliminary data based on the notification from the Hungarian authorities:

After take-off at about 4000feet (AGL -above ground level) 3 consecutive (within 1 second) loud bangs were heard by the crew, and ECAM (A320 Electronic Centralized Aircraft Monitoring display) caution was generated about “Eng. No.1 stall”. Crew also observed EGT (Exhaust gas temperature) over limits/increase. According applicable ECAM actions crew set thrust lever No.1 to idle. EGT was decreasing and settled at a normal value, therefore crew decided to keep engine No.1 running on idle power. Crew declared distress message “PAN” to ATC unit.Flight crew decided to divert to LHBP/BUD.During this time Engine No. 1 was running stable on idle power. About 7 minutes later ECAM caution advised EGT over limit on engine No.1. Crew shut down engine No.1. The in-flight engine shutdown was followed by an uneventful landing in LHBP/BUD.