Diminution de la puissance du moteur en montée initiale, virage à droite, décrochage

Responsible entity

France - BEA

Investigation progression Closed
Progress: 100%

The pilot carried out a local flight of around 46 min. A fuel leak during the flight due to the incorrect positioning of the fuel strainer seal meant that the fuel tanks progressively drained in an abnormal way (average engine consumption plus leak). In initial climb, the engine power decreased. The pilot turned right. During the turn, the microlight stalled and collided with the ground.

If the fuel strainer seal had been incorrectly positioned during a previous flight, the pilot would have been able to detect the consequences. However, the latter did not report any abnormal engine operation or over-consumption of fuel. It is therefore very likely that the fuel strainer was opened and its seal incorrectly repositioned prior to the accident flight, either during the pre-flight inspection or following the penultimate flight.